Backtested Material Engineering Datasheet

Hydrochloric Acid 100% vs EPDM Compatibility

CAS: 7647-01-0 Formula: HCl (Concentrated / Fuming) Chemical: Hydrochloric Acid 100% Material: EPDM Grade B

Verified chemical resistance rating (Acceptable with Operating Controls), thermal boundary limits (Ambient service (72°F / 22°C) preferred; monitor wear in continuous service), and material specification guide for EPDM exposed to Hydrochloric Acid 100% in Halogenated / Mineral Acid service.

Official Resistance Rating Grade B
B-Good Acceptable with Operating Controls
EPDM B-Good
Engineering Verdict — Acceptable with Operating Controls B-Good

Hydrochloric Acid 100% vs EPDM: B-Good

Exposing EPDM to Hydrochloric Acid 100% (Formula: HCl (Concentrated / Fuming), CAS: 7647-01-0) carries an official rating of B-Good (Acceptable with Operating Controls). Maximum recommended thermal operating limit: Ambient service (72°F / 22°C) preferred; monitor wear in continuous service. Best Grade A alternative materials for continuous or high-temperature service: Viton, PTFE, PVC, PVDF.

Verification Audit: Verified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Technical Specifications and Operating Parameters

Chemical Medium Hydrochloric Acid 100%
Chemical Formula HCl (Concentrated / Fuming)
CAS Registry Number 7647-01-0
Chemical Functional Class Halogenated / Mineral Acid
Wetted Material EPDM
Official Resistance Rating B-Good (Grade B)
Engineering Service Verdict Acceptable with Operating Controls
Max Temp and Concentration Limit Ambient service (72°F / 22°C) preferred; monitor wear in continuous service
Best Grade A Alternatives Viton, PTFE, PVC, PVDF
Backtest and Audit Verification Verified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Hydrochloric Acid 100% Cross-Material Comparison Matrix (9 Materials)

Direct benchmark ratings across all 9 reference industrial materials for Hydrochloric Acid 100%:

Polypropylene C-Fair
316 Stainless Steel D-Severe Effect
Viton (FKM) A-Excellent
PTFE (Teflon) A-Excellent
EPDM B-Good
PVC Type I A-Excellent
PVDF (Kynar) A-Excellent
Buna-N (Nitrile) C-Fair
HDPE C1-Fair
Material Name Compatibility Rating Service Verdict Temperature Limit Datasheet
Buna-N C-Fair Caution: Limited / Intermittent Service Only Ambient intermittent contact only; do not pressurize Report
EPDM B-Good Acceptable with Operating Controls Ambient service (72°F / 22°C) preferred; monitor wear in continuous service Report
HDPE C1-Fair Caution: Short-Term or Emergency Use Only Short-term exposure only; avoid continuous pressurized service Report
Polypropylene C-Fair Caution: Limited / Intermittent Service Only Ambient intermittent contact only; do not pressurize Report
PTFE A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
PVC A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
PVDF A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
Stainless Steel D-Severe Effect Incompatible — Immediate Failure Risk Not recommended at any temperature or concentration Report
Viton A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report

Chemical and Material Interaction Analysis

Engineering Compatibility Verdict

Hydrochloric Acid 100% vs EPDM: B – Good (Minor Effect / Conditional)

Summary Verdict: EPDM (Ethylene Propylene Diene Monomer) is rated B-Good (Acceptable with Operating Controls) when exposed to Hydrochloric Acid 100% (Formula: HCl (Concentrated / Fuming), CAS: 7647-01-0). Acceptable for low-pressure piping, static seals, and scheduled-maintenance components. Implement periodic visual and dimensional inspection.

Quick Engineering Specifications

Chemical MediaHydrochloric Acid 100%
Chemical FormulaHCl (Concentrated / Fuming)
CAS Registry Number7647-01-0
Chemical ClassificationHalogenated / Mineral Acid
Wetted MaterialEPDM (Ethylene Propylene Diene Monomer) (Synthetic Polar-Service Elastomer)
Official Resistance RatingB – Good (Minor Effect / Conditional) (Grade B)
Recommended Temperature WindowAmbient service (72°F / 22°C) preferred; monitor wear in continuous service (Material limit: -60°F to 300°F (-51°C to 149°C))
Top Grade-A AlternativesViton, PTFE, PVC, PVDF
Data Verification StatusVerified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Chemical & Material Interaction Analysis

Hydrochloric Acid 100% is classified as a halogenated / mineral acid (aggressive halide ion attack, pitting risk in metals, and acid hydrolysis). Used in acid pickling, descaling, semiconductor etching, and industrial chemical processing. When selecting wetted components for EPDM, engineers must account for both concentration-dependent chemical attack and thermal stress:

  • Reaction & Failure Mechanism: Exhibits minor chemical interaction—such as slight discoloration, mild dimensional swell, or slow uniform surface etching—that does not immediately compromise structural integrity.
  • Material Profile (EPDM): Outstanding resistance to polar fluids including ketones (acetone, MEK), alcohols, glycols, phosphate ester hydraulic fluids (Skydrol), alkalis, and dilute acids. However, exhibits rapid, catastrophic volumetric swelling and softening when exposed to petroleum oils, gasoline, diesel, kerosene, aliphatic/aromatic hydrocarbons, and chlorinated solvents.
  • Application Scope: Common wetted components include butterfly valve liners, O-rings, sanitary Tri-Clamp gaskets, caustic dosing hoses, and water/wastewater treatment seals.

Cross-Material Compatibility Comparison for Hydrochloric Acid 100%

To help you select the longest-lasting piping, valve lining, or O-ring seal for Hydrochloric Acid 100%, the table below compares EPDM against 8 other common industrial engineering materials:

Wetted Material Compatibility Rating Service Recommendation Material Temp Range
Polypropylene (PP Homopolymer & Copolymer)C-FairCaution: Limited / Intermittent Service Only32°F to 180°F (0°C to 82°C)
316 / 304 Austenitic Stainless SteelD-Severe EffectIncompatible — Immediate Failure Risk-325°F to 800°F (-198°C to 426°C)
Viton® (FKM Fluoroelastomer)A-ExcellentSafe for Continuous Industrial Service-15°F to 400°F (-26°C to 204°C)
PTFE (Teflon® / Polytetrafluoroethylene)A-ExcellentSafe for Continuous Industrial Service-328°F to 500°F (-200°C to 260°C)
EPDM (Ethylene Propylene Diene Monomer) (Current Page)B-GoodAcceptable with Operating Controls-60°F to 300°F (-51°C to 149°C)
PVC Type I (Unplasticized Polyvinyl Chloride / uPVC)A-ExcellentSafe for Continuous Industrial Service32°F to 140°F (0°C to 60°C)
PVDF (Kynar® / Polyvinylidene Fluoride)A-ExcellentSafe for Continuous Industrial Service-40°F to 280°F (-40°C to 138°C)
Buna-N (Nitrile / NBR Elastomer)C-FairCaution: Limited / Intermittent Service Only-40°F to 250°F (-40°C to 121°C)
HDPE (High-Density Polyethylene)C1-FairCaution: Short-Term or Emergency Use Only-60°F to 140°F (-51°C to 60°C)

Frequently Asked Questions (FAQ)

Is EPDM compatible with Hydrochloric Acid 100%?

EPDM is rated B-Good (Acceptable with Operating Controls) with Hydrochloric Acid 100% (Formula: HCl (Concentrated / Fuming), CAS: 7647-01-0). Exhibits minor chemical interaction—such as slight discoloration, mild dimensional swell, or slow uniform surface etching—that does not immediately compromise structural integrity. Acceptable for low-pressure piping, static seals, and scheduled-maintenance components. Implement periodic visual and dimensional inspection.

What is the best alternative material for handling Hydrochloric Acid 100%?

If EPDM does not meet your temperature or pressure requirements for Hydrochloric Acid 100%, the highest-rated Grade A alternatives are Viton, PTFE, PVC, PVDF. Always verify O-ring elastomers and metallic fasteners separately before full-scale deployment.

Technical Engineering FAQs: Hydrochloric Acid 100% vs EPDM

Click any question below for chemical failure-mode specifics, thermal derating limits, and material selection rules:

Can EPDM be specified for Hydrochloric Acid 100% process piping, valves, or gaskets?
EPDM is rated Grade B (B-Good) for Hydrochloric Acid 100% (Acceptable with Operating Controls). It is suitable for secondary transfer lines, static gaskets, and intermittent batch service up to Ambient service (72°F / 22°C) preferred; monitor wear in continuous service with routine inspection. For high-stress dynamic seals or higher temperatures, upgrade to Viton, PTFE, PVC, PVDF.
How do all 9 reference materials compare for Hydrochloric Acid 100% (CAS 7647-01-0)?
For Hydrochloric Acid 100% (HCl (Concentrated / Fuming), Halogenated / Mineral Acid), our cross-material compatibility matrix establishes the following ratings across all 9 engineering materials: Polypropylene: C-Fair | 316 Stainless Steel: D-Severe Effect | PTFE (Teflon): A-Excellent | PVDF (Kynar): A-Excellent | PVC Type I: A-Excellent | HDPE: C1-Fair | Viton (FKM): A-Excellent | EPDM: B-Good | Buna-N (Nitrile): C-Fair.