Backtested Material Engineering Datasheet

Carbon Disulfide vs Viton Compatibility

Verified chemical resistance rating (Safe for Continuous Industrial Service), thermal boundary limits (Up to 120°F (49°C) verified; up to material thermal limit in non-pressurized service), and material specification guide for Viton exposed to Carbon Disulfide in Inorganic Salt / Brine / Ionic Solution service.

Official Resistance Rating Grade A
A1-Excellent Safe for Continuous Industrial Service
Viton A1-Excellent
Engineering Verdict — Safe for Continuous Industrial Service A1-Excellent

Carbon Disulfide vs Viton: A1-Excellent

Exposing Viton to Carbon Disulfide (Formula: CS2, CAS: 75-15-0) carries an official rating of A1-Excellent (Safe for Continuous Industrial Service). Maximum recommended thermal operating limit: Up to 120°F (49°C) verified; up to material thermal limit in non-pressurized service. Best Grade A alternative materials for continuous or high-temperature service: Stainless Steel, PTFE, PVDF.

Verification Audit: Verified against Cole-Parmer, ISM & Graco industrial chemical resistance charts.

Technical Specifications and Operating Parameters

Chemical Medium Carbon Disulfide
Chemical Formula CS2
CAS Registry Number 75-15-0
Chemical Functional Class Inorganic Salt / Brine / Ionic Solution
Wetted Material Viton
Official Resistance Rating A1-Excellent (Grade A)
Engineering Service Verdict Safe for Continuous Industrial Service
Max Temp and Concentration Limit Up to 120°F (49°C) verified; up to material thermal limit in non-pressurized service
Best Grade A Alternatives Stainless Steel, PTFE, PVDF
Backtest and Audit Verification Verified against Cole-Parmer, ISM & Graco industrial chemical resistance charts.

Carbon Disulfide Cross-Material Comparison Matrix (9 Materials)

Direct benchmark ratings across all 9 reference industrial materials for Carbon Disulfide:

Polypropylene D-Severe Effect
316 Stainless Steel A1-Excellent
Viton (FKM) A1-Excellent
PTFE (Teflon) A-Excellent
EPDM D-Severe Effect
PVC Type I B-Good
PVDF (Kynar) A-Excellent
Buna-N (Nitrile) B-Good
HDPE D-Severe Effect
Material Name Compatibility Rating Service Verdict Temperature Limit Datasheet
Buna-N B-Good Acceptable with Operating Controls Ambient service (72°F / 22°C) preferred; monitor wear in continuous service Report
EPDM D-Severe Effect Incompatible — Immediate Failure Risk Not recommended at any temperature or concentration Report
HDPE D-Severe Effect Incompatible — Immediate Failure Risk Not recommended at any temperature or concentration Report
Polypropylene D-Severe Effect Incompatible — Immediate Failure Risk Not recommended at any temperature or concentration Report
PTFE A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
PVC B-Good Acceptable with Operating Controls Ambient service (72°F / 22°C) preferred; monitor wear in continuous service Report
PVDF A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
Stainless Steel A1-Excellent Safe for Continuous Industrial Service Up to 120°F (49°C) verified; up to material thermal limit in non-pressurized service Report
Viton A1-Excellent Safe for Continuous Industrial Service Up to 120°F (49°C) verified; up to material thermal limit in non-pressurized service Report

Chemical and Material Interaction Analysis

Engineering Compatibility Verdict

Carbon Disulfide vs Viton: A1 – Excellent (No Effect up to 120°F / 49°C)

Summary Verdict: Viton® (FKM Fluoroelastomer) is rated A1-Excellent (Safe for Continuous Industrial Service) when exposed to Carbon Disulfide (Formula: CS2, CAS: 75-15-0). Approved for primary wetted components including continuous-duty piping, bulk storage tanks, pump manifolds, and static/dynamic seals.

Quick Engineering Specifications

Chemical MediaCarbon Disulfide
Chemical FormulaCS2
CAS Registry Number75-15-0
Chemical ClassificationInorganic Salt / Brine / Ionic Solution
Wetted MaterialViton® (FKM Fluoroelastomer) (High-Performance Fluorinated Elastomer)
Official Resistance RatingA1 – Excellent (No Effect up to 120°F / 49°C) (Grade A)
Recommended Temperature WindowUp to 120°F (49°C) verified; up to material thermal limit in non-pressurized service (Material limit: -15°F to 400°F (-26°C to 204°C))
Top Grade-A AlternativesStainless Steel, PTFE, PVDF
Data Verification StatusVerified against Cole-Parmer, ISM & Graco industrial chemical resistance charts.

Chemical & Material Interaction Analysis

Carbon Disulfide is classified as an inorganic salt / brine / ionic solution (electrolytic corrosion risk in metals, especially chlorides/halides, while thermoplastics remain largely inert). Used in water treatment, chemical dosing, brine handling, and industrial process streams. When selecting wetted components for Viton, engineers must account for both concentration-dependent chemical attack and thermal stress:

  • Reaction & Failure Mechanism: Exhibits negligible weight change, zero surface crazing, and minimal dimensional swelling (<1%) across extended immersion testing.
  • Material Profile (Viton): Exceptional resistance to aliphatic and aromatic hydrocarbons, petroleum oils, concentrated mineral acids, and halogenated solvents at elevated temperatures. However, severely attacked by polar oxygenated solvents (acetone, MEK, ethyl acetate, THF), anhydrous ammonia, primary amines, and hot concentrated caustic soda via dehydrofluorination.
  • Application Scope: Common wetted components include O-ring static/dynamic seals, pump diaphragms, valve seats, flange gaskets, and chemical transfer hose liners.

Cross-Material Compatibility Comparison for Carbon Disulfide

To help you select the longest-lasting piping, valve lining, or O-ring seal for Carbon Disulfide, the table below compares Viton against 8 other common industrial engineering materials:

Wetted Material Compatibility Rating Service Recommendation Material Temp Range
Polypropylene (PP Homopolymer & Copolymer)D-Severe EffectIncompatible — Immediate Failure Risk32°F to 180°F (0°C to 82°C)
316 / 304 Austenitic Stainless SteelA1-ExcellentSafe for Continuous Industrial Service-325°F to 800°F (-198°C to 426°C)
Viton® (FKM Fluoroelastomer) (Current Page)A1-ExcellentSafe for Continuous Industrial Service-15°F to 400°F (-26°C to 204°C)
PTFE (Teflon® / Polytetrafluoroethylene)A-ExcellentSafe for Continuous Industrial Service-328°F to 500°F (-200°C to 260°C)
EPDM (Ethylene Propylene Diene Monomer)D-Severe EffectIncompatible — Immediate Failure Risk-60°F to 300°F (-51°C to 149°C)
PVC Type I (Unplasticized Polyvinyl Chloride / uPVC)B-GoodAcceptable with Operating Controls32°F to 140°F (0°C to 60°C)
PVDF (Kynar® / Polyvinylidene Fluoride)A-ExcellentSafe for Continuous Industrial Service-40°F to 280°F (-40°C to 138°C)
Buna-N (Nitrile / NBR Elastomer)B-GoodAcceptable with Operating Controls-40°F to 250°F (-40°C to 121°C)
HDPE (High-Density Polyethylene)D-Severe EffectIncompatible — Immediate Failure Risk-60°F to 140°F (-51°C to 60°C)

Frequently Asked Questions (FAQ)

Is Viton compatible with Carbon Disulfide?

Viton is rated A1-Excellent (Safe for Continuous Industrial Service) with Carbon Disulfide (Formula: CS2, CAS: 75-15-0). Exhibits negligible weight change, zero surface crazing, and minimal dimensional swelling (<1%) across extended immersion testing. Approved for primary wetted components including continuous-duty piping, bulk storage tanks, pump manifolds, and static/dynamic seals.

What is the best alternative material for handling Carbon Disulfide?

If Viton does not meet your temperature or pressure requirements for Carbon Disulfide, the highest-rated Grade A alternatives are Stainless Steel, PTFE, PVDF. Always verify O-ring elastomers and metallic fasteners separately before full-scale deployment.

Technical Engineering FAQs: Carbon Disulfide vs Viton

Click any question below for chemical failure-mode specifics, thermal derating limits, and material selection rules:

Can Viton be specified for Carbon Disulfide process piping, valves, or gaskets?
Yes. Because Viton achieves a Grade A (A1-Excellent) rating with Carbon Disulfide (Safe for Continuous Industrial Service), it is approved for continuous-duty wetted components including process piping, storage tanks, valve bodies, and seals within the recommended operating window (Up to 120°F (49°C) verified; up to material thermal limit in non-pressurized service).
How do all 9 reference materials compare for Carbon Disulfide (CAS 75-15-0)?
For Carbon Disulfide (CS2, Inorganic Salt / Brine / Ionic Solution), our cross-material compatibility matrix establishes the following ratings across all 9 engineering materials: Polypropylene: D-Severe Effect | 316 Stainless Steel: A1-Excellent | PTFE (Teflon): A-Excellent | PVDF (Kynar): A-Excellent | PVC Type I: B-Good | HDPE: D-Severe Effect | Viton (FKM): A1-Excellent | EPDM: D-Severe Effect | Buna-N (Nitrile): B-Good.