Backtested Material Engineering Datasheet

Tetrachloroethane vs HDPE Compatibility

CAS: 79-34-5 Formula: C2H2Cl4 (1,1,2,2-Tetrachloroethane) Chemical: Tetrachloroethane Material: HDPE Grade C

Verified chemical resistance rating (Caution: Short-Term or Emergency Use Only), thermal boundary limits (Short-term exposure only; avoid continuous pressurized service), and material specification guide for HDPE exposed to Tetrachloroethane in Halogenated Hydrocarbon / Refrigerant service.

Official Resistance Rating Grade C
C1-Fair Caution: Short-Term or Emergency Use Only
HDPE C1-Fair
Engineering Verdict — Caution: Short-Term or Emergency Use Only C1-Fair

Tetrachloroethane vs HDPE: C1-Fair

Exposing HDPE to Tetrachloroethane (Formula: C2H2Cl4 (1,1,2,2-Tetrachloroethane), CAS: 79-34-5) carries an official rating of C1-Fair (Caution: Short-Term or Emergency Use Only). Maximum recommended thermal operating limit: Short-term exposure only; avoid continuous pressurized service. Best Grade A alternative materials for continuous or high-temperature service: Viton, PTFE, PVDF.

Verification Audit: Verified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Technical Specifications and Operating Parameters

Chemical Medium Tetrachloroethane
Chemical Formula C2H2Cl4 (1,1,2,2-Tetrachloroethane)
CAS Registry Number 79-34-5
Chemical Functional Class Halogenated Hydrocarbon / Refrigerant
Wetted Material HDPE
Official Resistance Rating C1-Fair (Grade C)
Engineering Service Verdict Caution: Short-Term or Emergency Use Only
Max Temp and Concentration Limit Short-term exposure only; avoid continuous pressurized service
Best Grade A Alternatives Viton, PTFE, PVDF
Backtest and Audit Verification Verified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Tetrachloroethane Cross-Material Comparison Matrix (9 Materials)

Direct benchmark ratings across all 9 reference industrial materials for Tetrachloroethane:

Polypropylene C-Fair
316 Stainless Steel B-Good
Viton (FKM) A-Excellent
PTFE (Teflon) A-Excellent
EPDM D-Severe Effect
PVC Type I B-Good
PVDF (Kynar) A-Excellent
Buna-N (Nitrile) D-Severe Effect
HDPE C1-Fair
Material Name Compatibility Rating Service Verdict Temperature Limit Datasheet
Buna-N D-Severe Effect Incompatible — Immediate Failure Risk Not recommended at any temperature or concentration Report
EPDM D-Severe Effect Incompatible — Immediate Failure Risk Not recommended at any temperature or concentration Report
HDPE C1-Fair Caution: Short-Term or Emergency Use Only Short-term exposure only; avoid continuous pressurized service Report
Polypropylene C-Fair Caution: Limited / Intermittent Service Only Ambient intermittent contact only; do not pressurize Report
PTFE A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
PVC B-Good Acceptable with Operating Controls Ambient service (72°F / 22°C) preferred; monitor wear in continuous service Report
PVDF A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
Stainless Steel B-Good Acceptable with Operating Controls Ambient service (72°F / 22°C) preferred; monitor wear in continuous service Report
Viton A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report

Chemical and Material Interaction Analysis

Engineering Compatibility Verdict

Tetrachloroethane vs HDPE: C1 – Fair (Moderate Effect up to 120°F / 49°C)

Summary Verdict: HDPE (High-Density Polyethylene) is rated C1-Fair (Caution: Short-Term or Emergency Use Only) when exposed to Tetrachloroethane (Formula: C2H2Cl4 (1,1,2,2-Tetrachloroethane), CAS: 79-34-5). Not recommended for permanent pressurized piping or critical O-ring seals. Use only for short-duration flushing or non-critical gravity drain lines.

Quick Engineering Specifications

Chemical MediaTetrachloroethane
Chemical FormulaC2H2Cl4 (1,1,2,2-Tetrachloroethane)
CAS Registry Number79-34-5
Chemical ClassificationHalogenated Hydrocarbon / Refrigerant
Wetted MaterialHDPE (High-Density Polyethylene) (Linear Semi-Crystalline Polyolefin Thermoplastic)
Official Resistance RatingC1 – Fair (Moderate Effect up to 120°F / 49°C) (Grade C)
Recommended Temperature WindowShort-term exposure only; avoid continuous pressurized service (Material limit: -60°F to 140°F (-51°C to 60°C))
Top Grade-A AlternativesViton, PTFE, PVDF
Data Verification StatusVerified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Chemical & Material Interaction Analysis

Tetrachloroethane is classified as a halogenated hydrocarbon / refrigerant (high diffusivity and strong non-polar solvent swelling in polyolefins and standard rubbers). Used in vapor degreasing, refrigerant loops, chemical extraction, and polymer manufacturing. When selecting wetted components for HDPE, engineers must account for both concentration-dependent chemical attack and thermal stress:

  • Reaction & Failure Mechanism: Induces moderate chemical attack, noticeable elastomeric swelling (10%–20%), loss of tensile modulus, or measurable metal pitting/etching (20–50 mpy).
  • Material Profile (HDPE): High impact strength (even at sub-zero temperatures) and excellent resistance to mineral acids, caustics, salt brines, and alcohols. However, lower upper temperature limit (140°F/60°C) than Polypropylene, with susceptibility to permeation and environmental stress cracking in aromatic/chlorinated hydrocarbons and strong oxidizers.
  • Application Scope: Common wetted components include bulk chemical storage tanks, IBC totes, double-containment underground piping, and chemical drum liners.

Cross-Material Compatibility Comparison for Tetrachloroethane

To help you select the longest-lasting piping, valve lining, or O-ring seal for Tetrachloroethane, the table below compares HDPE against 8 other common industrial engineering materials:

Wetted Material Compatibility Rating Service Recommendation Material Temp Range
Polypropylene (PP Homopolymer & Copolymer)C-FairCaution: Limited / Intermittent Service Only32°F to 180°F (0°C to 82°C)
316 / 304 Austenitic Stainless SteelB-GoodAcceptable with Operating Controls-325°F to 800°F (-198°C to 426°C)
Viton® (FKM Fluoroelastomer)A-ExcellentSafe for Continuous Industrial Service-15°F to 400°F (-26°C to 204°C)
PTFE (Teflon® / Polytetrafluoroethylene)A-ExcellentSafe for Continuous Industrial Service-328°F to 500°F (-200°C to 260°C)
EPDM (Ethylene Propylene Diene Monomer)D-Severe EffectIncompatible — Immediate Failure Risk-60°F to 300°F (-51°C to 149°C)
PVC Type I (Unplasticized Polyvinyl Chloride / uPVC)B-GoodAcceptable with Operating Controls32°F to 140°F (0°C to 60°C)
PVDF (Kynar® / Polyvinylidene Fluoride)A-ExcellentSafe for Continuous Industrial Service-40°F to 280°F (-40°C to 138°C)
Buna-N (Nitrile / NBR Elastomer)D-Severe EffectIncompatible — Immediate Failure Risk-40°F to 250°F (-40°C to 121°C)
HDPE (High-Density Polyethylene) (Current Page)C1-FairCaution: Short-Term or Emergency Use Only-60°F to 140°F (-51°C to 60°C)

Frequently Asked Questions (FAQ)

Is HDPE compatible with Tetrachloroethane?

HDPE is rated C1-Fair (Caution: Short-Term or Emergency Use Only) with Tetrachloroethane (Formula: C2H2Cl4 (1,1,2,2-Tetrachloroethane), CAS: 79-34-5). Induces moderate chemical attack, noticeable elastomeric swelling (10%–20%), loss of tensile modulus, or measurable metal pitting/etching (20–50 mpy). Not recommended for permanent pressurized piping or critical O-ring seals. Use only for short-duration flushing or non-critical gravity drain lines.

What is the best alternative material for handling Tetrachloroethane?

If HDPE does not meet your temperature or pressure requirements for Tetrachloroethane, the highest-rated Grade A alternatives are Viton, PTFE, PVDF. Always verify O-ring elastomers and metallic fasteners separately before full-scale deployment.

Technical Engineering FAQs: Tetrachloroethane vs HDPE

Click any question below for chemical failure-mode specifics, thermal derating limits, and material selection rules:

Can HDPE be specified for Tetrachloroethane process piping, valves, or gaskets?
Exercise caution. HDPE carries a Grade C (C1-Fair) rating in Tetrachloroethane service (Caution: Short-Term or Emergency Use Only). Moderate swelling, mechanical softening, or measurable corrosion occurs under continuous exposure. Restrict use to short-term ambient contact (Short-term exposure only; avoid continuous pressurized service), and specify Viton, PTFE, PVDF for permanent installations.
How do all 9 reference materials compare for Tetrachloroethane (CAS 79-34-5)?
For Tetrachloroethane (C2H2Cl4 (1,1,2,2-Tetrachloroethane), Halogenated Hydrocarbon / Refrigerant), our cross-material compatibility matrix establishes the following ratings across all 9 engineering materials: Polypropylene: C-Fair | 316 Stainless Steel: B-Good | PTFE (Teflon): A-Excellent | PVDF (Kynar): A-Excellent | PVC Type I: B-Good | HDPE: C1-Fair | Viton (FKM): A-Excellent | EPDM: D-Severe Effect | Buna-N (Nitrile): D-Severe Effect.