Backtested Material Engineering Datasheet

Trichloroethane vs Buna-N Compatibility

CAS: 71-55-6 Formula: C2H3Cl3 (1,1,1-Trichloroethane) Chemical: Trichloroethane Material: Buna-N Grade D

Verified chemical resistance rating (Incompatible — Immediate Failure Risk), thermal boundary limits (Not recommended at any temperature or concentration), and material specification guide for Buna-N exposed to Trichloroethane in Halogenated Hydrocarbon / Refrigerant service.

Official Resistance Rating Grade D
D-Severe Effect Incompatible — Immediate Failure Risk
Buna-N D-Severe Effect
Engineering Verdict — Incompatible — Immediate Failure Risk D-Severe Effect

Trichloroethane vs Buna-N: D-Severe Effect

Exposing Buna-N to Trichloroethane (Formula: C2H3Cl3 (1,1,1-Trichloroethane), CAS: 71-55-6) carries an official rating of D-Severe Effect (Incompatible — Immediate Failure Risk). Maximum recommended thermal operating limit: Not recommended at any temperature or concentration. Best Grade A alternative materials for continuous or high-temperature service: Viton, PTFE, PVDF.

Verification Audit: Verified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Technical Specifications and Operating Parameters

Chemical Medium Trichloroethane
Chemical Formula C2H3Cl3 (1,1,1-Trichloroethane)
CAS Registry Number 71-55-6
Chemical Functional Class Halogenated Hydrocarbon / Refrigerant
Wetted Material Buna-N
Official Resistance Rating D-Severe Effect (Grade D)
Engineering Service Verdict Incompatible — Immediate Failure Risk
Max Temp and Concentration Limit Not recommended at any temperature or concentration
Best Grade A Alternatives Viton, PTFE, PVDF
Backtest and Audit Verification Verified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Trichloroethane Cross-Material Comparison Matrix (9 Materials)

Direct benchmark ratings across all 9 reference industrial materials for Trichloroethane:

Polypropylene C-Fair
316 Stainless Steel B-Good
Viton (FKM) A-Excellent
PTFE (Teflon) A-Excellent
EPDM D-Severe Effect
PVC Type I D-Severe Effect
PVDF (Kynar) A-Excellent
Buna-N (Nitrile) D-Severe Effect
HDPE C1-Fair
Material Name Compatibility Rating Service Verdict Temperature Limit Datasheet
Buna-N D-Severe Effect Incompatible — Immediate Failure Risk Not recommended at any temperature or concentration Report
EPDM D-Severe Effect Incompatible — Immediate Failure Risk Not recommended at any temperature or concentration Report
HDPE C1-Fair Caution: Short-Term or Emergency Use Only Short-term exposure only; avoid continuous pressurized service Report
Polypropylene C-Fair Caution: Limited / Intermittent Service Only Ambient intermittent contact only; do not pressurize Report
PTFE A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
PVC D-Severe Effect Incompatible — Immediate Failure Risk Not recommended at any temperature or concentration Report
PVDF A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
Stainless Steel B-Good Acceptable with Operating Controls Ambient service (72°F / 22°C) preferred; monitor wear in continuous service Report
Viton A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report

Chemical and Material Interaction Analysis

Engineering Compatibility Verdict

Trichloroethane vs Buna-N: D – Severe Effect (Do Not Use)

Summary Verdict: Buna-N (Nitrile / NBR Elastomer) is rated D-Severe Effect (Incompatible — Immediate Failure Risk) when exposed to Trichloroethane (Formula: C2H3Cl3 (1,1,1-Trichloroethane), CAS: 71-55-6). PROHIBITED for wetted service. Immediately substitute with an A-rated material shown in the cross-material comparison table below.

Quick Engineering Specifications

Chemical MediaTrichloroethane
Chemical FormulaC2H3Cl3 (1,1,1-Trichloroethane)
CAS Registry Number71-55-6
Chemical ClassificationHalogenated Hydrocarbon / Refrigerant
Wetted MaterialBuna-N (Nitrile / NBR Elastomer) (Acrylonitrile-Butadiene Copolymer Elastomer)
Official Resistance RatingD – Severe Effect (Do Not Use) (Grade D)
Recommended Temperature WindowNot recommended at any temperature or concentration (Material limit: -40°F to 250°F (-40°C to 121°C))
Top Grade-A AlternativesViton, PTFE, PVDF
Data Verification StatusVerified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Chemical & Material Interaction Analysis

Trichloroethane is classified as a halogenated hydrocarbon / refrigerant (high diffusivity and strong non-polar solvent swelling in polyolefins and standard rubbers). Used in vapor degreasing, refrigerant loops, chemical extraction, and polymer manufacturing. When selecting wetted components for Buna-N, engineers must account for both concentration-dependent chemical attack and thermal stress:

  • Reaction & Failure Mechanism: Causes rapid, catastrophic material failure—including severe dissolution, stress cracking, extreme volumetric blowout (>25% swell), or rapid pitting corrosion (>50 mpy).
  • Material Profile (Buna-N): Workhorse elastomer for petroleum-based hydraulic oils, motor oils, diesel, gasoline, aliphatic hydrocarbons (hexane, heptane), water, and salt brines. However, poor resistance to ozone/weathering and rapidly destroyed by ketones, esters, chlorinated hydrocarbons, aromatic solvents, and strong oxidizing acids.
  • Application Scope: Common wetted components include hydraulic O-rings, fuel transfer hoses, rotary shaft seals, oil gaskets, and general-purpose industrial pump elastomers.

Cross-Material Compatibility Comparison for Trichloroethane

To help you select the longest-lasting piping, valve lining, or O-ring seal for Trichloroethane, the table below compares Buna-N against 8 other common industrial engineering materials:

Wetted Material Compatibility Rating Service Recommendation Material Temp Range
Polypropylene (PP Homopolymer & Copolymer)C-FairCaution: Limited / Intermittent Service Only32°F to 180°F (0°C to 82°C)
316 / 304 Austenitic Stainless SteelB-GoodAcceptable with Operating Controls-325°F to 800°F (-198°C to 426°C)
Viton® (FKM Fluoroelastomer)A-ExcellentSafe for Continuous Industrial Service-15°F to 400°F (-26°C to 204°C)
PTFE (Teflon® / Polytetrafluoroethylene)A-ExcellentSafe for Continuous Industrial Service-328°F to 500°F (-200°C to 260°C)
EPDM (Ethylene Propylene Diene Monomer)D-Severe EffectIncompatible — Immediate Failure Risk-60°F to 300°F (-51°C to 149°C)
PVC Type I (Unplasticized Polyvinyl Chloride / uPVC)D-Severe EffectIncompatible — Immediate Failure Risk32°F to 140°F (0°C to 60°C)
PVDF (Kynar® / Polyvinylidene Fluoride)A-ExcellentSafe for Continuous Industrial Service-40°F to 280°F (-40°C to 138°C)
Buna-N (Nitrile / NBR Elastomer) (Current Page)D-Severe EffectIncompatible — Immediate Failure Risk-40°F to 250°F (-40°C to 121°C)
HDPE (High-Density Polyethylene)C1-FairCaution: Short-Term or Emergency Use Only-60°F to 140°F (-51°C to 60°C)

Frequently Asked Questions (FAQ)

Is Buna-N compatible with Trichloroethane?

Buna-N is rated D-Severe Effect (Incompatible — Immediate Failure Risk) with Trichloroethane (Formula: C2H3Cl3 (1,1,1-Trichloroethane), CAS: 71-55-6). Causes rapid, catastrophic material failure—including severe dissolution, stress cracking, extreme volumetric blowout (>25% swell), or rapid pitting corrosion (>50 mpy). PROHIBITED for wetted service. Immediately substitute with an A-rated material shown in the cross-material comparison table below.

What is the best alternative material for handling Trichloroethane?

If Buna-N does not meet your temperature or pressure requirements for Trichloroethane, the highest-rated Grade A alternatives are Viton, PTFE, PVDF. Always verify O-ring elastomers and metallic fasteners separately before full-scale deployment.

Technical Engineering FAQs: Trichloroethane vs Buna-N

Click any question below for chemical failure-mode specifics, thermal derating limits, and material selection rules:

Can Buna-N be specified for Trichloroethane process piping, valves, or gaskets?
Do not specify Buna-N for wetted service with Trichloroethane. It carries a Grade D (D-Severe Effect) rating (Incompatible — Immediate Failure Risk) due to rapid chemical attack, severe swelling, stress cracking, or structural dissolution. Substitute with Grade A materials such as Viton, PTFE, PVDF.
How do all 9 reference materials compare for Trichloroethane (CAS 71-55-6)?
For Trichloroethane (C2H3Cl3 (1,1,1-Trichloroethane), Halogenated Hydrocarbon / Refrigerant), our cross-material compatibility matrix establishes the following ratings across all 9 engineering materials: Polypropylene: C-Fair | 316 Stainless Steel: B-Good | PTFE (Teflon): A-Excellent | PVDF (Kynar): A-Excellent | PVC Type I: D-Severe Effect | HDPE: C1-Fair | Viton (FKM): A-Excellent | EPDM: D-Severe Effect | Buna-N (Nitrile): D-Severe Effect.