Backtested Material Engineering Datasheet

Nitric Acid (5-10%) vs PVDF Compatibility

CAS: 7697-37-2 Formula: HNO3 (5–10% aq.) Chemical: Nitric Acid (5-10%) Material: PVDF Grade A

Verified chemical resistance rating (Safe for Continuous Industrial Service), thermal boundary limits (Ambient to elevated operating temperatures within standard material limits), and material specification guide for PVDF exposed to Nitric Acid (5-10%) in Strong Oxidizing / Mineral Acid service.

Official Resistance Rating Grade A
A-Excellent Safe for Continuous Industrial Service
PVDF A-Excellent
Engineering Verdict — Safe for Continuous Industrial Service A-Excellent

Nitric Acid (5-10%) vs PVDF: A-Excellent

Exposing PVDF to Nitric Acid (5-10%) (Formula: HNO3 (5–10% aq.), CAS: 7697-37-2) carries an official rating of A-Excellent (Safe for Continuous Industrial Service). Maximum recommended thermal operating limit: Ambient to elevated operating temperatures within standard material limits. Best Grade A alternative materials for continuous or high-temperature service: Polypropylene, Stainless Steel, Viton, PTFE.

Verification Audit: Verified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Technical Specifications and Operating Parameters

Chemical Medium Nitric Acid (5-10%)
Chemical Formula HNO3 (5–10% aq.)
CAS Registry Number 7697-37-2
Chemical Functional Class Strong Oxidizing / Mineral Acid
Wetted Material PVDF
Official Resistance Rating A-Excellent (Grade A)
Engineering Service Verdict Safe for Continuous Industrial Service
Max Temp and Concentration Limit Ambient to elevated operating temperatures within standard material limits
Best Grade A Alternatives Polypropylene, Stainless Steel, Viton, PTFE
Backtest and Audit Verification Verified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Nitric Acid (5-10%) Cross-Material Comparison Matrix (9 Materials)

Direct benchmark ratings across all 9 reference industrial materials for Nitric Acid (5-10%):

Polypropylene A-Excellent
316 Stainless Steel A-Excellent
Viton (FKM) A-Excellent
PTFE (Teflon) A-Excellent
EPDM B-Good
PVC Type I A-Excellent
PVDF (Kynar) A-Excellent
Buna-N (Nitrile) D-Severe Effect
HDPE A-Excellent
Material Name Compatibility Rating Service Verdict Temperature Limit Datasheet
Buna-N D-Severe Effect Incompatible — Immediate Failure Risk Not recommended at any temperature or concentration Report
EPDM B-Good Acceptable with Operating Controls Ambient service (72°F / 22°C) preferred; monitor wear in continuous service Report
HDPE A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
Polypropylene A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
PTFE A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
PVC A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
PVDF A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
Stainless Steel A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report
Viton A-Excellent Safe for Continuous Industrial Service Ambient to elevated operating temperatures within standard material limits Report

Chemical and Material Interaction Analysis

Engineering Compatibility Verdict

Nitric Acid (5-10%) vs PVDF: A – Excellent (Fully Compatible)

Summary Verdict: PVDF (Kynar® / Polyvinylidene Fluoride) is rated A-Excellent (Safe for Continuous Industrial Service) when exposed to Nitric Acid (5-10%) (Formula: HNO3 (5–10% aq.), CAS: 7697-37-2). Approved for continuous fluid handling, bulk storage, valves, and sealing assemblies.

Quick Engineering Specifications

Chemical MediaNitric Acid (5-10%)
Chemical FormulaHNO3 (5–10% aq.)
CAS Registry Number7697-37-2
Chemical ClassificationStrong Oxidizing / Mineral Acid
Wetted MaterialPVDF (Kynar® / Polyvinylidene Fluoride) (High-Purity Semi-Crystalline Fluoropolymer)
Official Resistance RatingA – Excellent (Fully Compatible) (Grade A)
Recommended Temperature WindowAmbient to elevated operating temperatures within standard material limits (Material limit: -40°F to 280°F (-40°C to 138°C))
Top Grade-A AlternativesPolypropylene, Stainless Steel, Viton, PTFE
Data Verification StatusVerified against Cole-Parmer, ISM, Graco & CP Lab Safety industrial chemical resistance charts.

Chemical & Material Interaction Analysis

Nitric Acid (5-10%) is classified as a strong oxidizing / mineral acid (corrosive proton attack combined with strong oxidative potential). Used in chemical synthesis, metal pickling, pH neutralization, and industrial etching. When selecting wetted components for PVDF, engineers must account for both concentration-dependent chemical attack and thermal stress:

  • Reaction & Failure Mechanism: Chemically inert interface with no measurable corrosion, polymer chain scission, or elastomeric swell under standard operating conditions.
  • Material Profile (PVDF): Superior mechanical strength and abrasion resistance compared to PTFE, with exceptional resistance to halogens (wet/dry chlorine, bromine), strong acids, and oxidizers. However, attacked by strong polar aprotic solvents (acetone, MEK, DMF, DMSO, NMP), primary amines, and high-concentration caustic soda (NaOH >50%) which cause dehydrofluorination.
  • Application Scope: Common wetted components include high-purity acid distribution lines, wet-bench chemical etching systems, bleach/halogen injection quills, and magnetic-drive pump heads.

Cross-Material Compatibility Comparison for Nitric Acid (5-10%)

To help you select the longest-lasting piping, valve lining, or O-ring seal for Nitric Acid (5-10%), the table below compares PVDF against 8 other common industrial engineering materials:

Wetted Material Compatibility Rating Service Recommendation Material Temp Range
Polypropylene (PP Homopolymer & Copolymer)A-ExcellentSafe for Continuous Industrial Service32°F to 180°F (0°C to 82°C)
316 / 304 Austenitic Stainless SteelA-ExcellentSafe for Continuous Industrial Service-325°F to 800°F (-198°C to 426°C)
Viton® (FKM Fluoroelastomer)A-ExcellentSafe for Continuous Industrial Service-15°F to 400°F (-26°C to 204°C)
PTFE (Teflon® / Polytetrafluoroethylene)A-ExcellentSafe for Continuous Industrial Service-328°F to 500°F (-200°C to 260°C)
EPDM (Ethylene Propylene Diene Monomer)B-GoodAcceptable with Operating Controls-60°F to 300°F (-51°C to 149°C)
PVC Type I (Unplasticized Polyvinyl Chloride / uPVC)A-ExcellentSafe for Continuous Industrial Service32°F to 140°F (0°C to 60°C)
PVDF (Kynar® / Polyvinylidene Fluoride) (Current Page)A-ExcellentSafe for Continuous Industrial Service-40°F to 280°F (-40°C to 138°C)
Buna-N (Nitrile / NBR Elastomer)D-Severe EffectIncompatible — Immediate Failure Risk-40°F to 250°F (-40°C to 121°C)
HDPE (High-Density Polyethylene)A-ExcellentSafe for Continuous Industrial Service-60°F to 140°F (-51°C to 60°C)

Frequently Asked Questions (FAQ)

Is PVDF compatible with Nitric Acid (5-10%)?

PVDF is rated A-Excellent (Safe for Continuous Industrial Service) with Nitric Acid (5-10%) (Formula: HNO3 (5–10% aq.), CAS: 7697-37-2). Chemically inert interface with no measurable corrosion, polymer chain scission, or elastomeric swell under standard operating conditions. Approved for continuous fluid handling, bulk storage, valves, and sealing assemblies.

What is the best alternative material for handling Nitric Acid (5-10%)?

If PVDF does not meet your temperature or pressure requirements for Nitric Acid (5-10%), the highest-rated Grade A alternatives are Polypropylene, Stainless Steel, Viton, PTFE. Always verify O-ring elastomers and metallic fasteners separately before full-scale deployment.

Technical Engineering FAQs: Nitric Acid (5-10%) vs PVDF

Click any question below for chemical failure-mode specifics, thermal derating limits, and material selection rules:

Can PVDF be specified for Nitric Acid (5-10%) process piping, valves, or gaskets?
Yes. Because PVDF achieves a Grade A (A-Excellent) rating with Nitric Acid (5-10%) (Safe for Continuous Industrial Service), it is approved for continuous-duty wetted components including process piping, storage tanks, valve bodies, and seals within the recommended operating window (Ambient to elevated operating temperatures within standard material limits).
How do all 9 reference materials compare for Nitric Acid (5-10%) (CAS 7697-37-2)?
For Nitric Acid (5-10%) (HNO3 (5–10% aq.), Strong Oxidizing / Mineral Acid), our cross-material compatibility matrix establishes the following ratings across all 9 engineering materials: Polypropylene: A-Excellent | 316 Stainless Steel: A-Excellent | PTFE (Teflon): A-Excellent | PVDF (Kynar): A-Excellent | PVC Type I: A-Excellent | HDPE: A-Excellent | Viton (FKM): A-Excellent | EPDM: B-Good | Buna-N (Nitrile): D-Severe Effect.